BT35-11-7.1/4KW防爆轴流风机风量26210m3/h功率3KW转速960带支架,BT35-11-7.1 4KW 380V风量26210防爆轴流风机 机号 转速rpm 叶片角度 风量m3/h 风压Pa 配用电机 A声级Db(A) 型号 功率kw BT35-11-2.8 2900 35 3202 232 YSF-6300 0.25 75 1450 35 1605 60 YSF-5024 0.12 62 BT35-11-* 2900 35 4545 294 YSF-7122 0.55 79 1450 35 2273 74 YSF-5624 0.18 65 BT35-11-3.55 2900 35 6542 373 YSF-8022 0.75 82 1450 35 3265 93 YSF-6314 0.18 68 BT35-11-4 2900 35 9336 474 YF90S-2 1.1 85 1450 35 4687 119 YSF-7114 0.25 70 BT35-11-4.5 1450 35 6658 150 YSF-7124 0.37 73 BT35-11-5 1450 35 9133 185 YSF-8024 0.75 76 960 35 6104 81 YSF-8026 0.37 68 BT35-11-5.6 1450 35 12812 232 YF90S-4 1.1 79 960 35 8471 101 YSF-8026 0.37 71 BT35-11-6.3 1450 35 1825 294 YF100L-4 1.5 82 960 35 12082 128 YF90S-6 0.75 74 BT35-11-7.1 1450 35 26120 373 YF112M-4 3 84 960 35 17296 164 YF90S-6 1.1 78 BT35-11-8 1450 35 37070 474 YF132M-4 4 86 960 35 24739 208 YF112M-6 2.2 79 BT35-11-9 960 35 35227 263 YF132M1-6 4 82 BT35-11-10 960 35 48326 324 YF160M-6 5.5 83 BT35-11-11.2 960 35 67892 407 YF160L-6 7.5 88 安装与使用 1、 首先检查框架、风叶有无变形,扇叶转动是否灵活,有无摩擦现象。检查所有紧固件是否齐全、拧紧,应有防爆合格证编号。 2、 线路电压必须与电机上额定电压相符。 3、 用500V兆欧表检查电动机的绝缘电阻,其电阻值若小于50MΩ,则应用烘干法或短路电流法进行干燥处理,使其绝缘电阻大于5 MΩ。 4、 必须配用小型防爆开关做电源开关,或将普通开关安装于室外无爆炸性危险的地方。 5、 接电源的电缆外径应与密封圈相符,拧紧、压紧螺母后应保证密封圈与电缆间、出线间咀无间隙,否则将失去隔爆性能。 6、 装配时应保证防爆间隙小于0.2mm,更换电机轴承的润滑脂,其润滑脂牌号为ZG-2H复合钙基润。 7、 防爆电动机非接线部分不可随意拆卸,接线时,打开接线室的盖,穿入引线接到端子上,接好后,盖上盖拧紧螺钉使其隔爆面间隙小于0.2mm,再上紧出线器,使引线不能窜动。 8、 使用中的排风扇应经常清扫电机上粉尘及其它积聚物,以免影响散热。 9、 长期不用的排风扇重新使用时,应按说明书再检查一遍,合适后方可使用。 注意:安装时,注意隔爆面,装配时隔爆面须涂204-1防锈油脂。所有防爆面不得有损伤或锈蚀,否则将失去防爆性能,如有损伤或锈蚀现象需按《防爆电气设备防爆面缺陷处理的规定》进行修补